CIER0418.002 Eltek Rectiverter 6kVA 230V Marine 1ph MB 26ARMS / 348ARMS

Place of Origin China
Brand Name Eltek
Certification IEC/EN 62368-1:2020/AC:2020/A11:2020
Model Number CIER0418.002
Minimum Order Quantity 10
Price USD3600-8600
Packaging Details Original Packed by Carton
Delivery Time 1 week * depends on quantity
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 200sets/month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Model 6 KVA, 230 V Part Number CIER0418.002
AC Voltage (default) / (adjustable Range) 230 VAC / 200 - 240 VAC Frequency (default Inverter Mode) 50 Hz(adaptive)
Frequency (set-able Inverter Mode) 50Hz Or 60Hz Power Maximum(continuous / Overload (<15s) 60kW (75kVA) /112kVA
Current Maximum (continuous/ Overload (<15s) 10.9ARMS/16.3ARMSper Module Current (maximum) Quick Trip (20ms)1) 109A (10x Nominal)per Module
THD < 1.5 % At Resistive Load Output Power 33.0 KW
Current (maximum @VOUT≤ 48 VDC) 687.5A
High Light

Eltek Rectiverter 6kVA

,

Eltek Rectiverter 230V

,

CIER0418.002

You can tick the products you need and communicate with us in the message board.
Model 6 KVA, 230 V
Part number CIER0418.002
Voltage (default) / (adjustable range)1) 230 VAC / 200 - 240 VAC
Frequency (default inverter mode) 50Hz, 60Hz or last synced 50/60Hz (adaptive)
Frequency (set-able inverter mode) 50Hz, 60Hz or last synced 50/60Hz (adaptive)
Power maximum (continuous / overload (<15s) ) 4800 W (6000 VA) / 8000 VA
Current maximum (continuous / overload (<15s) ) 26ARMS / 34,8ARMS
Current (maximum) Quick trip (20ms) 120A (6 x nominal)
Hold up (Voltage dips) (before switching to battery) > 5 ms @ 4800W load
THD < 1.5 % at resistive load
Output features Fuse in L and N, Hot pluggableAC Distribution: 12x6 A, C characteristics 2 pole breakerGround fault alarm relay on AC output (Residual Current Relay)
Voltage (range) 53.5 VDC / 43 - 58 VDC
Power (maximum @nominal input) 600 W
Current (maximum @VOUT ≤ 48 VDC) 12,5 A
Hold up time, maximum output power >10ms; VOUT > 41 VDC
Output features Short circuit proof, Over voltage Shutdown1x 125 A, C characteristics 2 pole battery breaker with 24V external ESD trip
Extended battery kit PN: 350055 Additional 1*125 A, 2 pole battery breaker with battery looms
AC Mains Input Voltage (single phase) 185 - 275 VAC
AC Current (at nominal output voltage) 29 ARMS 3)
Frequency (default: sync range) 47-53 & 57-63 Hz
Frequency (set-able: sync range) 47-53 Hz, 57-63 Hz or both (adaptive)
Power Factor / THD > 0.99 at 50% load or more / < 3.5%
DC Voltage nominal / extended range (no overload)2) 45 - 58 VDC / 40 - 45 VDC
DC Current (maximum) 128 A / 180A during overload (15s)
Input features Fuse in L and N, Hot pluggable, Varistor, Hot pluggableDual single phase input; A and B feed (changeover device controlled by feed A)
Efficiency >96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC))
Manual bypass switch 63 A (make before break)
Colour RAL 7035
Protection Class IP 33
Battery backup time (at maximum AC power) 30-60 min
Operating temperature -10 to +45°C (+14 to +113°F), humidity 5 - 95% RH non-condensing
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxDxH] / Weight 600 x 600 x 900mm (23,7 x 23,7 x 35,5”) / 70 kg (155 lbs)
Electrical safety EN 60950-1, EN 62040-1
EMC ETSI EN 300 386 V.1.6.1, FCC CFR 47 Part 15EN 61000-6-1/-2/-3/-4
Environment ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2)RoHS (2011/65/EU) and WEEE (2002/96/EC) compliant
Approvals DNV-OS-D202, Ch.2 Sec. 4 (DNV 2.4)o Temperature Cl. Bo Humidity Cl. Bo Vibration Cl. AEMC Class A (pending approvals in next version EMC Class B & ABS)
Leave a Message
Model 6 KVA, 230 V
Product Description

Rectiverter 6kVA Marine 1ph MB 230V CIER0418.002 230 VAC / 200 - 240 VAC 4800 W (6000 VA) / 8000 VA26ARMS / 34 8ARMS

  • The Rectiverter power module combines both AC and DC feed into one common unit. Simultaneously it provides AC backup power for 230 VAC or 115 VAC loads, and 48 VDC power for battery charging.
  • AC and DC output limits can be set according to the attached load, where the limitation for AC load is set to max 6 kVA with possibility to set recharge values for battery banks up to max 0,6 kWCIER0418.002 Eltek Rectiverter 6kVA 230V Marine 1ph MB 26ARMS / 348ARMS 0